| GAS SHUTOFF CONTROL BOX INSTALLATION (Continued)
See FIGURE 18 for the following steps:
4. Plug the valve into the connector on the Gas Shutoff Control Box.
5. Connect the interconnect cable or Optional Receiver Board into the Gas Shutoff Control Box.
6. If Interconnect Cable is used, route the cable from Gas Shutoff Control Box to the Main CPU board. Spade lugs on the interconnect cable connect to terminal strip P1-5 & 7 of the Main CPU board. (See FIGURE 3 page 5)
7. Plug the power cord from the stove into the Gas Shutoff Control Box and then the power cord for the Gas Shutoff Box into the wall outlet.
SONIC GAS SHUTOFF
Description:
To convert the standard shutoff to a remote sonic version, the standard interface cable is replaced with the Sonic Receiver Assembly.
Typical interface is interchangeable for both the interconnect cable and the Sonic Receiver board. Either interface connection plugs into the electric shutoff, depending on which interface option is chosen. In some cases a sonic version of the shutoff device may be required. If this is the case, the audible alarm is required to shut off the stove via the optional Sonic Receiver Board. (See FIGURE 9) |
Arming/ Resetting Gas Shutoff Assembly
1. Turn power “ON” to the stove.
CAUTION: “GAS WILL BE FLOWING TO THE STOVE WHEN PERFORMING THE NEXT STEP”
2. The “Gas Flow” indicator light should be lit. If not, push the “Power Reset” switch ( first ) and then the Valve Reset” switch (second) to arm the control box.
Note: In the event that the gas shutoff is activated or an interruption in power occurs, it must be reset.
See System Checkout Procedures on Page 16 & 17 |